Stainless Steel Discs in Factory-assembled Cartridge for Medium-duty Applications

John Crane’s Metastream T Series metallic membrane couplings, incorporate scalloped, stainless-steel, flexible membranes.  This design gives the most flexible solution for high-torque and misalignment conditions.  The range of TSK/TSC has been specifically designed to meet the exacting standards of API 610 (ISO 13709) and ISO 14691.  With an excellent power to weight ratio and fit-and-forget reliability, the TSK/TSC coupling is ideally suited to meet the pumping, motor, and turbine drive power transmission in oil and gas, petrochemical, power generation, and other critical process industries.

 

TSC/TLC TDS TSCS IOM Extended Guard Ring IOM


Recherche de documents

Caractéristiques

  • California Residents: PROPOSITION 65 WARNING
  • Easy to fit
  • Intrinsic balance meets AGMA class 9
  • Ideally suited to pump applications
  • High misalignment capability.
  • Low imposed forces on machinery, leading to reduced machinery vibration and maximized bearing life.
  • Stainless steel flexible membranes for maximum life.
  • Cartridge transmission unit eases assembly and gives repeatable balance.
  • Overload collars are fitted to protect the flexible membrane in case of severe torsional overload.
  • Anti-fly retention of the spacer in the unlikely event of membrane failure.
  • Puller holes incorporated into hubs as standard.
  • Self-locking feature for security allows the bolts to be used repeatedly without compromising their integrity.
  • Compression and jacking bolt features for easy installation and removal of spacer assembly as standard.

Paramètres

ARBRE MAXIMUM

194 mm/6,94"

Couple maximum

118 300 lbf po (13 369 Nm)

COUPLE DE SURCHARGE OPTIMUM

295 800 lbf po (33 423 Nm)

LIMITES DE VITESSE

25 500 tr/min

LIMITES DE TEMPÉRATURE

-55 à 150 °C/-67 à 302 °F

Applications recommandées

  • Pompes de traitement
  • Moteurs électriques
  • Réducteurs
  • Turbines à vapeur
  • Compresseurs centrifuges
  • Autres compresseurs
  • Machines à entraînement
  • Autres équipements rotatifs
  • Générateurs

Nous contacter